Journal of Endodontics
Volume 28, Issue 2 , Pages 111-115, February 2002

Comparison of Two Ultrasonic Instruments for Post Removal

Dr. Dixon is a former graduate student in the Department of Endodontics, School of Dentistry, University of Washington, Seattle, WA, and is currently in private practice in Modesto, CA. Dr. Kaczkowski is a senior electrical engineer, Applied Physics Laboratory, School of Dentistry, University of Washington, Seattle, WA. Dr. Nicholls is a professor, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA. Dr. Harrington is professor and chairman in the Department of Endodontics and director of the Graduate Endodontics Program, School of Dentistry, University of Washington, Seattle, WA.

The relative performance of two different ultrasonic units commonly used clinically for post removal was evaluated using tips designed specifically for post vibration. Twenty-four extracted maxillary and mandibular cuspids with crowns removed at the labial cementoenamel junction were treated endodontically. Post spaces were made 10 mm into the roots before cementing a 16 mm #5 (0.050-inch) Para-Post with zinc phosphate cement. The teeth were divided into three similar groups of eight. Post retention was assessed in group 1. Ultrasonic vibration was applied to groups 2 and 3 until post removal. The average force required to dislodge the posts from the teeth in group 1 (control group, no ultrasound) was 40.5 kg (SD = 12.3 kg). The average time for post removal in group 2 (Spartan) was 4:52 min (SD = 2:26). The average time for post removal in group 3 (Enac) was 1:31 min (SD = 0:34). The difference between groups 2 and 3 was statistically significant (p < 0.005). Use of ultrasonic tips designed for post vibration and maximization of audible sound level during ultrasonic treatment of posts seem to play an important role in the effectiveness and efficiency of post removal. The results obtained indicate that both the Enac ultrasonic unit with the ST-09 vibration tip and the Spartan ultrasonic unit with the Analytic VT-S tip were effective. Nevertheless, the Enac ultrasonic unit with the ST-09 vibration tip was clearly more efficient under these study conditions, resulting in typical post removal times of <2 min.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 20.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This study was supported by a grant from the Washington Dental Service Foundation. Support was also received from the Graduate Endodontics Fund, University of Washington, School of Dentistry, Seattle, WA.

PII: S0099-2399(05)60595-X

doi:10.1097/00004770-200202000-00016

Journal of Endodontics
Volume 28, Issue 2 , Pages 111-115, February 2002