Journal of Endodontics
Volume 34, Issue 5, Supplement , Pages e17-e31 , May 2008

Root Canal Debridement: An Online Study Guide

References 

  1. Robinson D, Goerig AC, Neaverth EJ. Endodontic access: an update, part I. Compendium. 1989;10:290–296
  2. Robinson D, Goerig AC, Neaverth EJ. Endodontic access: an update, part II. Compendium. 1989;10:328–3
  3. Mauger MJ, Waite RM, Alexander JB, Schindler WG. Ideal endodontic access in mandibular incisors. J Endod. 1999;25:206–207
  4. Schroeder KP, Walton RE, Rivera EM. Straight line access and coronal flaring: effect on canal length. J Endod. 2002;28:474–476
  5. Nielson CJ, Shahmohammadi K. The effect of mesio-distal chamber dimension on access preparation in mandibular incisors. J Endod. 2005;31:88–90
  6. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am. 1974;18:269–296
  7. Weine FS, Kelly RF, Lio PJ. The effect of preparation procedures on original canal shape and on apical foramen shape. J Endod. 1975;1:255–262
  8. Coffae KP, Brilliant JD. The effect of serial preparation versus non-serial preparation of tissue removal in the root canals of extracted mandibular human molars. J Endod. 1975;1:211–214
  9. Walton RE. Histological evaluation of different methods of enlarging the pulp canal space. J Endod. 1976;2:304–311
  10. Allison DA, Weber CR, Walton RE. The influence of the method of canal preparation on the quality of apical and coronal obturation. J Endod. 1979;5:298–304
  11. Moodnik RM, Dorn SO, Feldman MJ, Levey M, Borden BG. Efficacy of biomechanical instrumentation: a scanning electron microscopic study. J Endod. 1976;2:261–266
  12. Esposito JV. Apical violation in periapical “area” cases. Dent Clin North Am. 1990;34:171–177
  13. Leseberg DA, Montgomery S. The effects of CanalMaster, Flex-R, and K-flex instrumentation on root canal configuration. J Endod. 1991;17:59–65
  14. Torabinejad M. Passive step-back technique. Oral Surg Oral Med Oral Pathol. 1994;77:398–401
  15. Roland DD, Andelin WE, Browning DF, Hsu GR, Torabinejad M. The effect of preflaring on the rates of separation of 0.04 taper nickel titanium instruments. J Endod. 2002;28:543–545
  16. Usman N, Baumgartner JC, Marshall JG. Influence of instrument size on root canal debridement. J Endod. 2004;30:110–112
  17. Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod. 2004;30:559–567
  18. Baugh D, Wallace J. The role of apical instrumentation in root canal treatment: a review of the literature. J Endod. 2005;31:333–340
  19. Hulsmann M, Peters OA, Dummer MH. Mechanical preparation of root canals: shaping goals, techniques and means. Endod Topics. 2005;10:30–76
  20. Gulabivala K, Patel B, Evans G, Ng YL. Effects of mechanical and chemical procedures on root canal surfaces. Endod Topics. 2005;10:103–122
  21. Mickel AK, Chogle S, Liddle J, Huffaker K, Jones JJ. The role of apical size determination and enlargement in the reduction of intracanal bacteria. J Endod. 2007;33:21–23
  22. Abou-Rass M, Jastrab RJ. The use of rotary instruments as auxiliary aids to root canal preparation of molars. J Endod. 1982;8:78–82
  23. Mullaney TP. Instrumentation of finely curved canals. Dent Clin North Am. 1979;23:575–592
  24. Leeb J. Canal orifice enlargement as related to biomechanical preparation. J Endod. 1983;9:463–470
  25. Stabholz A, Rotstein I, Torabinejad M. Effect of preflaring on tactile detection of the apical constriction. J Endod. 1995;21:92–94
  26. Davis RD, Marshall JG. Baumgartner JC (Effect of early coronal flaring on working length change in curved canals using rotary nickel–titanium versus stainless steel instruments). J Endod. 2002;28:438–442
  27. Roland DD, Andelin WE, Browning DF, Hsu GR, Torabinejad M. The effect of preflaring on the rate of separation for 0.04 taper nickel titanium rotary instrumentation. J Endod. 2002;28:543–545
  28. Goerig AC, Michelich RJ, Schultz HH. Instrumentation of root canals in molar using the step-down technique. J Endod. 1982;8:550–554
  29. Morgan LF, Montgomery S. An evaluation of the crown-down pressureless technique. J Endod. 1984;10:491–498
  30. Del Bello TP, Wang N, Roane JB. Crown–down tip design and shaping. J Endod. 2003;29:513–518
  31. Roane JB, Sabala CL, Duncanson MG. The balanced force concept for instrumentation of curved canals. J Endod. 1985;11:203–211
  32. Southard DW, Oswald RJ, Natkin R. Instrumentation of curved molar root canals with the Roane technique. J Endod. 1987;13:479–489
  33. Imura N, Kato AS, Novo NF, Hata G, Uemura M, Toda T. A comparison of mesial molar root canal preparations using two engine-driven instruments and the balanced-force technique. J Endod. 2001;27:627–631
  34. Walia H, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod. 1988;14:346–351
  35. Himel VT, Ahmed KM, Wood DM, Alhadainy HA. An evaluation of nitinol and stainless steel files used by dental students during a laboratory proficiency exam. Oral Surg Oral Med Oral Pathol. 1995;79:232–237
  36. Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand–file instrumentation using computed tomography. J Endod. 1996;22:369–375
  37. Coleman CL, Svec TA, Rieger MR, Suchina JA, Wang MM, Glickman GN. Analysis of nickel–titanium versus stainless steel instrumentation by means of direct digital imaging. J Endod. 1996;22:603–607
  38. Pettiette MT, Metzger Z, Phillips C, Trope M. Endodontic complications of root canal therapy performed by dental students with stainless-steel K-files and nickel-titanium hand files. J Endod. 1999;25:230–234
  39. Glosson CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod. 1995;21:146–151
  40. Short JA, Morgan LA, Baumgartner JC. A comparison of canal centering ability of four instrumentation techniques. J Endod. 1997;23:503–507
  41. Thompson SA, Dummer PHM. Shaping ability of ProFile .04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals (Part 1 & Part 2). Int Endod J. 1997;30:1–15
  42. Hinrichs RE, Walker WA, Schindler WG. A comparison of amounts of apically extruded debris using handpiece-driven nickel-titanium instrument systems. J Endod. 1998;24:102–106
  43. Mandel E, Adib–Yazdi M, Benhamou LM, Lachkar T, Mesgouez C, Sobel M. Rotary NiTi Profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. Int Endod J. 1999;32:436–443
  44. Rodig T, Hulsmann M, Muhge M, Schafers F. Quality of preparation of oval distal root canals in mandibular molars using nickel-titanium instruments. Int Endod J. 2002;35:919–928
  45. Haikel Y, Serfaty R, Bateman G, Senger B, Allemann C. Dynamic and cyclic fatigue of engine driven rotary NiTi Endodontic instruments. J Endod. 1999;25:434–440
  46. Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel–titanium endodontic instruments. J Endod. 1997;23:77–85
  47. Mize SB, Clement DJ, Pruett JP, Carnes DL. Effects of sterilization on clinic fatigue of rotary nickel-titanium endodontic instruments. J Endod. 1998;24:843–848
  48. Senia ES, Wildey WL. The LightSpeed root canal instrumentation system. Endod Topics. 2005;10:148–150
  49. Buchanan LS. ProSystem GT: design, technique, and advantages. Endod Topics. 2005;10:168–175
  50. Gambarini G. The K3 rotary nickel titanium instrument system. Endod Topics. 2005;10:179–182
  51. Ruddle CJ. The ProTaper technique. Endod Topics. 2005;10:187–190
  52. Senia ES, Marshall FJ, Rosen S. The solvent action of sodium hypochlorite on pulp tissue of extracted teeth. Oral Surg Oral Med Oral Pathol. 1971;31:96–103
  53. Hand RE, Smith ML, Harrison JW. Analysis of the effect of dilution on the necrotic tissue dissolution property of sodium hypochlorite. J Endod. 1978;4:60–64
  54. Harrison JW, Svec TA, Baumgartner JC. Analysis of clinical toxicity of endodontic irrigants. J Endod. 1978;4:6–11
  55. Rosenfeld EF, James GA, Burch BS. Vital pulp tissue response to sodium hypochlorite. J Endod. 1978;4:140–146
  56. Trepagnier CM, Madden RM, Lazzari EP. Quantitative study of sodium hypochlorite as an in vitro endodontic irrigant. J Endod. 1977;3:194–196
  57. Harrison JW, Hand RE. The effect of dilution and organic matter on the antibacterial property of 5.25% sodium hypochlorite. J Endod. 1981;7:128–132
  58. Gordon TM, Darmato D, Christner P. Solvent effect of various dilutions of sodium hypochlorite on vital and necrotic tissue. J Endod. 1981;7:466–469
  59. Svec TA, Harrison JW. The effect of effervescence on debridement of the apical regions of root canals in single- rooted teeth. J Endod. 1981;7:335–340
  60. Cunningham WT, Joseph SW. Effect of temperature on the bactericidal action of sodium hypochlorite endodontic irrigant. Oral Surg. 1980;50:569–571
  61. Cunningham WT, Balekjian AY. Effect of temperature on collagen-dissolving ability of sodium hypochlorite endodontic irrigant. Oral Surg. 1980;49:175–177
  62. Baker NA, Eleazer PD, Averbach RE, Seltzer S. Scanning electron microscopic study of the efficacy of various irrigating solutions. J Endod. 1975;1:127–135
  63. Shih M, Marshall FJ, Rosen S. The bactericidal efficiency of sodium hypochlorite as an endodontic irrigant. Oral Surg Oral Med Oral Pathol. 1970;29:613–619
  64. Raphael D, Wong TA, Moodnik R, Borden BG. The effect of temperature on the bactericidal efficiency of sodium hypochlorite. J Endod. 1981;7:330–334
  65. Harrison JW. Irrigation of the root canal system. Dent Clin North Am. 1984;28:797–808
  66. Baumgartner JC, Cuenin PR. Efficacy of several concentrations of sodium hypochlorite for root canal irrigation. J Endod. 1992;18:605–612
  67. Johnson BR, Remeikis NA. Effective shelf-life of prepared sodium hypochlorite solution. J Endod. 1993;19:40–43
  68. Ohara PK, Torabinejad M, Kettering JD. Antibacterial effects of various endodontic irrigants on selected anaerobic bacteria. Endod Dent Traumatol. 1993;9:95–100
  69. Piskin B, Turkun M. Stability of various sodium hypochlorite solutions. J Endod. 1995;21:253–255
  70. Kahn FH, Rosenberg PA, Gliksberg J. An in vitro evaluation of the irrigating characteristics of ultrasonic and subsonic handpieces and irrigating needles and probes. J Endod. 1995;21:277–280
  71. Gambarini G, De Luca M, Gerosa R. Chemical stability of heated sodium hypochlorite endodontic irrigants. J Endod. 1998;24:432–434
  72. Buck RA, Cai J, Eleazer PD, Staat RH, Hurst HE. Detoxification of endotoxin by endodontic irrigants and calcium hydroxide. J Endod. 2001;27:325–327
  73. Zamany A, Safavi K, Spangberg LSW. The effect of chlorhexidine as an endodontic disinfectant. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2003;96:578–581
  74. Hulsmann M, Heckendorff M, Lennon A. Chelating agents in root canal treatment: mode of action and indications for their use. Int Endod J. 2003;36:810–830
  75. Ercan E, Ozekinci T, Atakul F, Gul K. Antibacterial activity of 2% chlorhexidine gluconate and 5.25% sodium hypochlorite in infected root canals: in vivo study. J Endod. 2004;30:84–87
  76. Torabinejad M, Khademi AA, Babagoli J, et al. A new solution for the removal of the smear layer. J Endod. 2003;29:170–175
  77. Torabinejad M, Khademi A, Bakland L, Shabahang S. The effect of various concentrations of sodium hypochlorite on the ability of MTAD to remove the smear layer. J Endod. 2003;29:233–239
  78. Shabahang S, Pouresmail M, Torabinejad M. In vitro antimicrobial efficacy of MTAD and sodium hypochlorite. J Endod. 2003;29:450–452
  79. Haapasalo M, Endal U, Zandi H, Coil JM. Eradication of endodontic infection by instrumentation and irrigation solutions. Endod Topics. 2005;10:77–102
  80. Zehnder M. Root canal irrigants. J Endod. 2006;32:389–398
  81. Nielson BA, Baumgartner JC. Comparison of the EndoVac system to needle irrigation of root canals. J Endod. 2007;33:611–615
  82. Blank LW, Tenc JI, Pelleu GB. Reliability of electronic measuring devices in endodontic therapy. J Endod. 1975;1:141–145
  83. Trope M, Rabie G, Tronstad L. Accuracy of an electronic apex locator under controlled clinical conditions. Endod Dent Traumatol. 1985;1:142–145
  84. Fouad AF, Krell KV, McKendry DJ, Koorbusch GF, Olson RA. A clinical evaluation of five electronic root length measuring instruments. J Endod. 1990;16:446–449
  85. McDonald NJ. The electronic determination of working length. Dent Clin North Am. 1992;36:293–307
  86. Fouad AF, Rivera EM, Krell KV. Accuracy of the Endex with variations in canal irrigants and foramen size. J Endod. 1993;19:63–67
  87. Mayeda DL, Simon JH, Aimar DF, Finley K. In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator. J Endod. 1993;19:545–548
  88. Shabahang S, Goon WWY, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endod. 1996;22:616–618
  89. Jenkins JA, Walker WA, Schindler WG, Flores CM. An in vitro evaluation of the accuracy of the Root ZX in the presence of various irrigants. J Endod. 2001;27:209–211
  90. Garofalo RR, Ede EN, Dorn SO, Kuttler S. Effect of electronic apex locators on cardiac pacemaker function. J Endod. 2002;28:831–833
  91. Welk AR, Baumgartner JC, Marshall JG. An in vivo comparison of two frequency-based electronic apex locators. J Endod. 2003;29:497–500
  92. Gordon MPJ, Chandler NP. Review—electronic apex locators. Int Endod J. 2004;37:425–437
  93. Tselnik M, Baumgartner JC, Marshall JG. An evaluation of Root ZX and Elements Diagnostic apex locators. J Endod. 2005;31:507–509
  94. Williams CB, Joyce AP, Roberts S. A comparison between in vitro radiographic working length determination and measurement after extraction. J Endod. 2006;32:624–627
  95. Wilson BL, Broberg C, Baumgartner JC, Harris C, Kron J. Safety of electronic apex locators and pulp testers in patients with implanted cardiac pacemakers or cardioverter/defibrillators. J Endod. 2006;32:847–852
  96. Richman MJ. Use of ultrasonics in root canal therapy and root resection. J Dent Med. 1957;12:12–18
  97. Martin H. Ultrasonic disinfection of the root canal. Oral Surg Oral Med Oral Pathol. 1976;42:92–99
  98. Weller RN, Brady JM, Bernier WE. Efficacy of ultrasonic cleaning. J Endod. 1980;6:740–743
  99. Cameron JA. The use of ultrasound in the cleaning of root canals: a clinical report. J Endod. 1982;8:472–474
  100. Cunningham WT, Martin H, Forrest WR. Evaluation of root canal debridement by the endosonic ultrasonic synergistic system. Oral Surg. 1982;53:401–404
  101. Cymerman JJ, Jerome LA, Moodnik RM. A scanning electron microscope study comparing the efficacy of hand instrumentation with ultrasonic instrumentation of the root canal. J Endod. 1983;9:327–331
  102. Stamos DG, Haasch GC, Chenail B, Gerstein H. Endosonics: clinical impressions. J Endod. 1985;11:181–187
  103. Goodman A, Reader A, Beck M, Melfi R, Meyers W. An in vitro comparison of the efficacy of the step-back technique versus a step-back/ultrasonic technique in human mandibular molars. J Endod. 1985;11:249–256
  104. Chenail BL, Teplitsky PE. Endosonics in curved root canals. J Endod. 1985;11:369–374
  105. Tronstad L, Barnett F, Schwartzben L, Frasca P. Effectiveness and safety of a sonic vibratory endodontic instrument. Endod Dent Traumatol. 1985;1:69–76
  106. Barnett F, Godick R, Tronstad L. Clinical suitability of a sonic vibratory endodontic instrument. Endod Dent Traumatol. 1985;1:77–81
  107. Martin H, Cunningham WT. Endosonics—the ultrasonic synergistic system of endodontics. Endod Dent Traumatol. 1985;1:201–206
  108. Reynolds MA, Madison S, Walton RE, Krell KV, Rittman BR. An in vitro histological comparison of the step-back, sonic, and ultrasonic instrumentation techniques in small, curved root canals. J Endod. 1987;13:307–314
  109. Ahmad M, Pitt Ford TR, Crum LA. Ultrasonic debridement of root canals: acoustic streaming and its possible role. J Endod. 1987;13:490–499
  110. Walmsley AD. Ultrasound and root canal treatment: the need for scientific evaluation. Int Endod J. 1987;20:105–111
  111. Lev R, Reader A, Beck M, Meyers W. An in vitro comparison of the step-back technique versus a step-back/ultrasonic technique for 1 and 3 minutes. J Endod. 1987;13:523–530
  112. Haidet J, Reader A, Beck M, Meyers W. An in vivo comparison of the step-back technique versus a step-back/ultrasonic technique in human mandibular molars. J Endod. 1989;15:195–199
  113. Metzler RS, Montgomery S. The effectiveness of ultrasonic and calcium hydroxide for the debridement of human mandibular molars. J Endod. 1989;15:373–378
  114. Archer R, Reader A, Nist R, Beck M, Meyers WJ. An in vivo evaluation of the efficacy of ultrasound after step-back preparation in mandibular molars. J Endod. 1992;18:549–552
  115. Lumley PJ, Walmsley AD, Walton RE, Rippin JW. Effect of pre-curving endosonic files on the amount of debris and smear layer remaining in curved root canals. J Endod. 1992;18:616–619
  116. Ahmad M, Roy RA, Kamarudin AG, Safar M. The vibratory pattern of ultrasonic files driven piezoelectrically. Int Endod J. 1993;26:120–124
  117. Gutarts R, Nusstein J, Reader A, Beck M. In vivo debridement efficacy of ultrasonic irrigation following hand-rotary instrumentation in human mandibular molars. J Endod. 2005;31:166–170
  118. Plotino G, Pameijer CH, Maria Grande N, Somma F. Ultrasonics in endodontics: a review of the literature. J Endod. 2007;33:81–95
  119. Munley PJ, Goodell GG. Comparsion of passive ultrasonic debridement between fluted and nonfluted instruments in root canals. J Endod. 2007;33:578–580
  120. McComb D, Smith DC. A preliminary scanning electron microscopic study of root canals after endodontic procedures. J Endod. 1975;1:238–242
  121. Mader CL, Baumgartner JC, Peters DD. Scanning electron microscopic evaluation of root canal smeared layer on root canal walls. J Endod. 1984;10:477–483
  122. Cunningham WT, Martin H. A scanning electron microscope evaluation of root canal debridement with the endosonic ultrasonic synergistic system. Oral Surg Oral Med Oral Pathol. 1982;53:527–531
  123. Cameron JA. The use of ultrasonics in the removal of the smear layer: a scanning electron microscope study. J Endod. 1983;9:289–292
  124. Wayman BE, Kopp WM, Pinero GJ, Lazzari EP. Citric and lactic acids as root canal irrigants in vitro. J Endod. 1979;5:258–265
  125. Baumgartner JC, Brown CM, Mader CL, Peters DD, Shulman JD. A scanning electron microscopic evaluation of root canal debridement using saline, sodium hypochlorite, and citric acid. J Endod. 1984;10:525–531
  126. White RR, Goldman M, Lin PS. The influence of the smeared layer upon dentinal tubule penetration by plastic filling materials. J Endod. 1984;10:558–562
  127. Kennedy WA, Walker WA, Gough RW. Smear layer removal effects on apical leakage. J Endod. 1986;12:21–27
  128. Czonstkowsky M, Wilson EO, Holstein FA. The smear layer in endodontics. Dent Clin North Am. 1990;34:13–25
  129. Gencoglu N, Samani S, Gunday M. Evaluation of sealing properties of Thermafil and Ultrafil techniques in the absence or presence of smear layer. J Endod. 1993;19:599–603
  130. Drake DR, Wiemann AH, Rivera EM, Walton RE. Bacterial retention in canal walls in vitro: effect of smear layer. J Endod. 1994;20:78–82
  131. Sen BH, Wesselink PR, Turkun M. The smear layer: a phenomenon in root canal therapy. Int Endod J. 1995;28:141–148
  132. Calas P, Rochd T, Druilhet P, Azais JM. In vitro adhesion of two strains of Prevotella nigrescens to the dentin of the root canal. J Endod. 1998;24:112–115
  133. Sen BH, Buyukyilmaz T. The effect of 4% titanium tetrefluoride solution on root canal walls—a preliminary investigation. J Endod. 1998;24:239–243
  134. Peters OA, Barbakow F. Effects of irrigation on debris and smear layer on canal walls prepared by two rotary techniques: a scanning electron microscopic study. J Endod. 2000;25:6–10
  135. Torabinejad M, Handysides R, Ali Khademi A, Bakland L. Clinical implications of the smear layer in endodontics: a review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002;94:658–666
  136. Torabinejad M, Cho Y, Khademi AA, Bakland LK, Shabahang S. The effect of various concentrations of sodium hypochlorite on the ability of MTAD to remove the smear layer. J Endod. 2003;29:233–239
  137. Kokkas AB, Boutsioukis AC, Vassiliadis LP, Stavrianos CK. The influence of the smear layer on dentinal tubule penetration depth by three different root canal sealers: an in vitro study. J Endod. 2004;30:100–102
  138. Crumpton BJ, Goodell GG, McClanahan SB. Effects on smear layer and debris removal with varying volumes of 17% REDTA after rotary instrumentation. J Endod. 2005;31:536–538
  139. Shahravan A, Haghdoost A, Adl A, Rahimi H, Shadifar F. Effect of smear layer on sealing ability of canal obturation: a systematic review and meta-analysis. J Endod. 2007;33:96–105
  140. Spangberg L, Engstrom B, Langeland K. Biologic effects of dental materials, toxicity and antimicrobial effect of endodontic antiseptics in vitro. Oral Surg Oral Med Oral Pathol. 1973;36:856–871
  141. Spangberg L, Rutberg M, Rydinge E. Biologic effects of endodontic antimicrobial agents. J Endod. 1979;5:166–175
  142. Wesley DJ, Marshall FJ, Rosen S. The quantitation of formocresol as a root canal medicament. Oral Surg. 1970;29:603–612
  143. 's-Gravenmade EJ. Some biochemical considerations of fixation in endodontics. J Endod. 1975;1:233–237
  144. Maddox DL, Walton RE, Davis CO. Incidence of posttreatment endodontic pain related to medicaments and other factors. J Endod. 1977;3:447–452
  145. Harrison JW, Bellizzi R, Osetek EM. The clinical toxicity of endodontic medicaments. J Endod. 1979;5:42–47
  146. Walton RE. Intracanal medicaments. Dent Clin North Am. 1984;28:783–796
  147. Bystrom A, Claesson R, Sundqvist G. The antibacterial effect of camphorated paramonochlorophenol, camphorated phenol and calcium hydroxide in the treatment of infected root canals. Endod Dent Traumatol. 1985;1:170–175
  148. Sjogren U, Figdor D, Spangberg L, Sundqvist G. The antimicrobial effect of calcium hydroxide as a short-term intracanal dressing. Int Endod J. 1991;24:119–125
  149. Chong BS, Pitt Ford TR. The role of intracanal medication in root canal treatment. Int Endod J. 1992;25:97–106
  150. Safavi KE, Nichols FC. Effect of calcium hydroxide on bacterial lipopolysaccharide. J Endod. 1993;19:76–78
  151. Evans MD, Baumgartner JC, Khemaleelakul S, Xia T. Efficacy of calcium hydroxide: chlorhexidine paste as an intracanal medication in bovine dentin. J Endod. 2003;29:338–339
  152. Law A, Messer H. An evidence-based analysis of the antibacterial effectiveness of intracanal medicaments. J Endod. 2004;30:689–694
  153. Sathorn C, Parashos P, Messer H. Antibacterial efficacy of calcium hydroxide intracanal dressing: a systematic review and meta-analysis. Int Endod J. 2007;40:2–10
  154. Rosenberg B, Murray PE, Namerow K. The effect of calcium hydroxide root filling on dentin fracture strength. Dent Traumatol. 2007;23:26–29

 Correspondence: JOE Editorial Board

 JEndodontics@UTHSCSA.edu

PII: S0099-2399(07)00475-X

doi: 10.1016/j.joen.2007.05.010

Journal of Endodontics
Volume 34, Issue 5, Supplement , Pages e17-e31 , May 2008