Volume 36, Issue 5 , Pages 880-883, May 2010

Analyzing Endosonic Root Canal File Oscillations: An In Vitro Evaluation

  • Simon C. Lea, BSc (Hons), MSc, PhD, CSci, CPhys, MInstP

      Affiliations

    • Corresponding Author InformationAddress requests for reprints to Dr Simon C. Lea, School of Dentistry, University of Birmingham, St. Chad's Queensway, Birmingham, B4 6NN, United Kingdom.
  • ,
  • A. Damien Walmsley, BDS, MSc, PhD, FDSRCPS
  • ,
  • Philip J. Lumley, BDS, MDentSci, PhD, FDSRCPS

School of Dentistry, University of Birmingham, Birmingham, United Kingdom

published online 02 March 2010.

Abstract 

Introduction

Passive ultrasonic irrigation may be used to improve bacterial reduction within the root canal. The technique relies on a small file being driven to oscillate freely within the canal and activating an irrigant solution through biophysical forces such as microstreaming. There is limited information regarding a file's oscillation patterns when operated while surrounded by fluid as is the case within a canal root.

Methods

Files of different sizes (#10 and #30, 27 mm and 31 mm) were connected to an ultrasound generator via a 120° file holder. Files were immersed in a water bath, and a laser vibrometer set up with measurement lines superimposed over the files. The laser vibrometer was scanned over the oscillating files. Measurements were repeated 10 times for each file/power setting used.

Results

File mode shapes are comprised of a series of nodes/antinodes, with thinner, longer files producing more antinodes. The maximum vibration occurred at the free end of the file. Increasing generator power had no significant effect on this maximum amplitude (p > 0.20). Maximum displacement amplitudes were 17 to 22 μm (#10 file, 27 mm), 15 to 21 μm (#10 file, 31 mm), 6 to 9 μm (#30 file, 27 mm), and 5 to 7 μm (#30, 31 mm) for all power settings. Antinodes occurring along the remaining file length were significantly larger at generator power 1 than at powers 2 through 5 (p < 0.03).

Conclusions

At higher generator powers, energy delivered to the file is dissipated in unwanted vibration resulting in reduced vibration displacement amplitudes. This may reduce the occurrence of the biophysical forces necessary to maximize the technique's effectiveness.

Key Words: Endosonics, laser vibrometry, oscillation patterns, ultrasonics

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 20.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Supported by a research grant from the UK Engineering and Physical Sciences Research Council (EP/F020090/1).

PII: S0099-2399(09)01104-2

doi:10.1016/j.joen.2009.12.027

Journal of Endodontics
Volume 36, Issue 5 , Pages 880-883, May 2010