Scanning Electron Microscopic Analysis of the Integrity of the Root-end Surface after Root-end Management Using a Piezoelectric Device: A Cadaveric Study

  • Massimo Del Fabbro, BSc, PhD

      Affiliations

    • IRCCS Galeazzi Orthopaedic Institute, Dental Clinic, CRSO (Centro di Ricerca per la Salute Orale), Department of Health Technologies, University of Milan, Milan, Italy
    • Corresponding Author InformationAddress reprint requests to Massimo Del Fabbro, BSc, PhD, University of Milano, Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, 20161 Milan, Italy.
  • ,
  • Igor Tsesis, DMD

      Affiliations

    • Department of Endodontology, Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel
  • ,
  • Gabriele Rosano, DDS

      Affiliations

    • IRCCS Galeazzi Orthopaedic Institute, Dental Clinic, CRSO (Centro di Ricerca per la Salute Orale), Department of Health Technologies, University of Milan, Milan, Italy
  • ,
  • Monica Bortolin, BMT

      Affiliations

    • IRCCS Galeazzi Orthopaedic Institute, Dental Clinic, CRSO (Centro di Ricerca per la Salute Orale), Department of Health Technologies, University of Milan, Milan, Italy
  • ,
  • Silvio Taschieri, MD, DDS

      Affiliations

    • IRCCS Galeazzi Orthopaedic Institute, Dental Clinic, CRSO (Centro di Ricerca per la Salute Orale), Department of Health Technologies, University of Milan, Milan, Italy

published online 30 August 2010.

Abstract 

Introduction

The introduction of piezoelectric instruments in endodontic surgery allowed clinicians to manage the bone tissue with precision reducing the risk of damaging soft tissues. Although such instruments can also be used to prepare root-end cavity, few information is available on the effect of piezosurgery on dentine. This cadaveric study investigated the integrity of root apices after root-end cavity preparation by piezoelectric instruments at different device settings.

Methods

Fifty maxillary anterior teeth underwent endodontic treatment and apical resection in situ. Ten teeth were used as control. Retrograde cavities were prepared in 40 teeth (10 per group). In three groups, the piezoelectric device was set at constant vibration mode (CV), and three power levels were used. In another experimental group (n = 10), vibration + pulsation mode (VP) was selected, and low power was used. Each root was duplicated and analyzed by scanning electron microscopy for the presence of cracks and marginal chipping.

Results

The number of cracks was significantly higher in the VP group, whereas no significant difference was found among CV groups. No difference between groups was found for crack type. The VP group showed a significantly poorer quality of cavity margin respect to the CV groups.

Conclusion

Constant vibration mode is recommended for retrograde preparation with piezosurgery.

Key Words: Apical surgery, piezosurgery, quality of cavity margin, root-end fracture, root-end surface, scanning electron microscopic analysis

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 20.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0099-2399(10)00594-7

doi:10.1016/j.joen.2010.06.028

Journal of Endodontics
Volume 36, Issue 10 , Pages 1693-1697, October 2010